TB0428 Phase Detection Relay : Différence entre versions

[version en cours de rédaction][version en cours de rédaction]
(Page créée avec « {{Tuto Details |Main_Picture=TB0428_Phase_Detection_Relay_0437_phase_detection_relay.jpg |Main_Picture_annotation={"version":"2.4.6","objects":[{"type":"image","version":"... »)
 
 
Ligne 6 : Ligne 6 :
 
|Tags=TB0428, Phase, Detection, Relay
 
|Tags=TB0428, Phase, Detection, Relay
 
}}
 
}}
<translate>== What is a Phase Detection Relay? ==
+
<translate>==What is a Phase Detection Relay?==
The lamps labelled “>Umax” and “<Umin” indicate if the voltage supply exceeds the %age set on the dials. The dials are normally set to 90% and 110%. In this photo, the >Umax lamp is on showing that the input supply voltage is too high.
+
The lamps labelled “>Umax” and “<Umin” indicate if the voltage supply exceeds the percentage set on the dials. The dials are normally set to 90% and 110%.  
 +
In the photo, the >Umax lamp is on showing that the input supply voltage is too high.{{#annotatedImageLight:Fichier:TB0428 Phase Detection Relay 0437 phase detection relay.jpg|0=499px|hash=|jsondata=|mediaClass=Image|type=frameless|align=center|src=https://stuga.dokit.app/images/3/39/TB0428_Phase_Detection_Relay_0437_phase_detection_relay.jpg|href=./Fichier:TB0428 Phase Detection Relay 0437 phase detection relay.jpg|resource=./Fichier:TB0428 Phase Detection Relay 0437 phase detection relay.jpg|caption=|size=499px}}
  
  
It will not do any damage to the machine if the threshold needs to be increased to 85% or 115% to get the machine running.
+
It will not do any damage to the machine if the threshold needs to be increased to min 85% or max 115% if a customer has a varying supply
  
  
Ligne 16 : Ligne 17 :
  
  
The dials T1 and T2 set the internal timer to trigger power off after a certain amount of time in fault condition.</translate>
+
The dials T1 and T2 set the internal timer to trigger power off after a certain amount of time in fault condition, this should be between 0.1 to 0.5s</translate>
 
{{PageLang
 
{{PageLang
 +
|Language=en
 
|SourceLanguage=none
 
|SourceLanguage=none
 
|IsTranslation=0
 
|IsTranslation=0
|Language=en
 
 
}}
 
}}
 
{{AddComments}}
 
{{AddComments}}

Version actuelle datée du 28 février 2020 à 17:35

Auteur avatarGareth Green | Dernière modification 28/02/2020 par Gareth Green en cours de rédaction

The phase detection relay shuts the power down to the machine if one phase is missing, or if the voltage drops or exceeds a set threshold.

What is a Phase Detection Relay?

The lamps labelled “>Umax” and “<Umin” indicate if the voltage supply exceeds the percentage set on the dials. The dials are normally set to 90% and 110%.

In the photo, the >Umax lamp is on showing that the input supply voltage is too high.

TB0428 Phase Detection Relay 0437 phase detection relay.jpg


It will not do any damage to the machine if the threshold needs to be increased to min 85% or max 115% if a customer has a varying supply


If this does not work, competent person can measure the voltage on each phase to see where the issue is.


The dials T1 and T2 set the internal timer to trigger power off after a certain amount of time in fault condition, this should be between 0.1 to 0.5s

Commentaires