Mul File Specification - ioDef : Différence entre versions

[version en cours de rédaction][version en cours de rédaction]
Ligne 69 : Ligne 69 :
 
|-
 
|-
 
|7
 
|7
|Stoppable  
+
|Stoppable
 
|Bool
 
|Bool
 
|Defines if an output should "Pause" during and alarm and then back on again after a restart.
 
|Defines if an output should "Pause" during and alarm and then back on again after a restart.
Ligne 107 : Ligne 107 :
 
2 - Saw side only
 
2 - Saw side only
 
<br />{{Info|...This value is important for the stoppable output function. If one side of the machine is paused due to an alarm, you do not want the other side to pause at the same time (it needs to continue running)}}
 
<br />{{Info|...This value is important for the stoppable output function. If one side of the machine is paused due to an alarm, you do not want the other side to pause at the same time (it needs to continue running)}}
 
  
 
|-
 
|-
Ligne 113 : Ligne 112 :
 
|Cable Ref
 
|Cable Ref
 
|5A
 
|5A
|If a value is entered in this field, this will change the service screen display to this text. this allows legacy older machines with different cable numbering (Y1, X2, etc) to maintain the correct numbers on screen, bu have a the standard IO reference in the background  
+
|If a value is entered in this field, this will change the service screen display to this text. this allows legacy older machines with different cable numbering (Y1, X2, etc) to maintain the correct numbers on screen, bu have a the standard IO reference in the background
 
|}
 
|}
  
Ligne 124 : Ligne 123 :
 
!IO Screen
 
!IO Screen
 
!Notes
 
!Notes
!
 
 
|-
 
|-
 
|0-5
 
|0-5
Ligne 130 : Ligne 128 :
 
|On this original screen, the inputs and outputs are fixed on the left and right side of this screen, so the location is also determined by whether it is an input or an output
 
|On this original screen, the inputs and outputs are fixed on the left and right side of this screen, so the location is also determined by whether it is an input or an output
 
The number relates to the column
 
The number relates to the column
|
 
 
|-
 
|-
 
|10-19
 
|10-19
 
|Spindle Screen
 
|Spindle Screen
 
|The digit after the 1 relates to the column on the spindle IO screen
 
|The digit after the 1 relates to the column on the spindle IO screen
|
 
 
|-
 
|-
|
 
 
|
 
|
 
|
 
|

Version du 25 novembre 2019 à 14:02

Auteur avatarGareth Green | Dernière modification 22/02/2023 par Gareth Green en cours de rédaction

Pas encore d'image

Specification of the ioDef.mul file

Function

The ioDef file is used to define which Inputs and Outputs a particular machine has. The IO definitions are used for

  • Displaying the IO as panels on the Service screen of the control software for diagnostics
  • References in the alarms file for building machine-specific alarm modes
  • References in the spindle / tooling setup to define spindle on / off outputs and sensor inputs, etc
  • References in the xholds file to define x axis areas where an output cannot function
  • References in the axis setup to identify the home input for a particular axis

Each line is an individual input or output

Field Format

Field Specification
No Name Format Notes
1 Code Name 10A Code name used to reference IO

The name needs to be short enough to fit on the IO screen buttons

Later software / machines prefixed with InX_ or OuX_ where X is the module letter

2 Ref No 3N 3 digit reference code for the IO. this code is critical as it is used to link everything together. It is a unique code for an input or output function that is used across the range of Stuga machines.
3 Type 1N 0 - Disabled

1 - Input

2 -Output

4 Node 2N ** Nextmove E100 / ESB systems only - not used on Beckhoff ***

This is the CAN Node hardware that the IO is referenced on

0 is the Main Nextmove controller

5 Channel 2N ** Nextmove E100 / ESB systems only - not used on Beckhoff ***

The hardware channel on the node that the IO is referenced to

...On a Beckhoff machine, the IO references are linked to the hardware using the Visual Studio Interface

6 Inverted Bool Defines if the input is inverted - the state will be inverse in all calculations. Use with extreme caution
7 Stoppable Bool Defines if an output should "Pause" during and alarm and then back on again after a restart.

Outputs such as conveyor belts and blowers should pause when an alarm occurs, then restart once start is pressed

Other outputs such as clamps need to stay on to hold the position during an alarm

8 Column 2N Column / screen that the IO reference will appear on the service screen. See below
9 Row 2N Row that the IO appears on
10 Keypress 1A Shortcut Key on keyboard that will toggle the output on and off is press while service screen is active
11 Log Bool *** DO NOT USE ***
12 Location 1N Location of the output on a flowline style machine that has 2 sides

0 - All sides (default)

1 - MH side only

2 - Saw side only


...This value is important for the stoppable output function. If one side of the machine is paused due to an alarm, you do not want the other side to pause at the same time (it needs to continue running)
13 Cable Ref 5A If a value is entered in this field, this will change the service screen display to this text. this allows legacy older machines with different cable numbering (Y1, X2, etc) to maintain the correct numbers on screen, bu have a the standard IO reference in the background

Column Numbering

The columns are given a code number to identify bot the column number on the screen and the screen that they appear on

Range IO Screen Notes
0-5 Main Service Screen On this original screen, the inputs and outputs are fixed on the left and right side of this screen, so the location is also determined by whether it is an input or an output

The number relates to the column

10-19 Spindle Screen The digit after the 1 relates to the column on the spindle IO screen


Commentaires