PC Configuration - Flowline D : Différence entre versions

[version en cours de rédaction][version en cours de rédaction]
(Page créée avec « {{Tuto Details |Main_Picture=TM003_Flowline_Overview_flowline.jpg |Main_Picture_annotation={"version":"2.4.6","objects":[{"type":"image","version":"2.4.6","originX":"left"... »)
 
Ligne 2 : Ligne 2 :
 
|Main_Picture=TM003_Flowline_Overview_flowline.jpg
 
|Main_Picture=TM003_Flowline_Overview_flowline.jpg
 
|Main_Picture_annotation={"version":"2.4.6","objects":[{"type":"image","version":"2.4.6","originX":"left","originY":"top","left":2,"top":45,"width":1475,"height":831,"fill":"rgb(0,0,0)","stroke":null,"strokeWidth":0,"strokeDashArray":null,"strokeLineCap":"butt","strokeDashOffset":0,"strokeLineJoin":"miter","strokeMiterLimit":4,"scaleX":0.41,"scaleY":0.41,"angle":0,"flipX":false,"flipY":false,"opacity":1,"shadow":null,"visible":true,"clipTo":null,"backgroundColor":"","fillRule":"nonzero","paintFirst":"fill","globalCompositeOperation":"source-over","transformMatrix":null,"skewX":0,"skewY":0,"crossOrigin":"","cropX":0,"cropY":0,"src":"https://stuga.dokit.app/images/4/4c/TM003_Flowline_Overview_flowline.jpg","filters":[]}],"height":450.12126111560224,"width":600}
 
|Main_Picture_annotation={"version":"2.4.6","objects":[{"type":"image","version":"2.4.6","originX":"left","originY":"top","left":2,"top":45,"width":1475,"height":831,"fill":"rgb(0,0,0)","stroke":null,"strokeWidth":0,"strokeDashArray":null,"strokeLineCap":"butt","strokeDashOffset":0,"strokeLineJoin":"miter","strokeMiterLimit":4,"scaleX":0.41,"scaleY":0.41,"angle":0,"flipX":false,"flipY":false,"opacity":1,"shadow":null,"visible":true,"clipTo":null,"backgroundColor":"","fillRule":"nonzero","paintFirst":"fill","globalCompositeOperation":"source-over","transformMatrix":null,"skewX":0,"skewY":0,"crossOrigin":"","cropX":0,"cropY":0,"src":"https://stuga.dokit.app/images/4/4c/TM003_Flowline_Overview_flowline.jpg","filters":[]}],"height":450.12126111560224,"width":600}
|Description=<translate>PC network configuration of the Flowline following a "full windows upgrade". This replaces both the MH side PC, as in Flowline B plus the saw side PC.</translate>
+
|Description=<translate>PC network configuration of the Flowline following using a Beckhoff TwinCAT3 system which controls both the saw and windows side.</translate>
 
|Categories=Specification
 
|Categories=Specification
 
|Tags=FlowlineD, PC, Configuration
 
|Tags=FlowlineD, PC, Configuration
 
}}
 
}}
<translate>=Summary=
+
<translate>Following a second wave of obsolescence, this upgrade replaces all the control components with a Beckhoff control system. The major change to this system is that it uses one central system to control both sides of the machine.
Setup follows the format of [[https://stuga.dokit.app/w/FlowlineB%7CFlowlineB]] with two independent machines with independent control systems. In FlowlineC, the saw side ACEPC is replaced with a similar PC to the MH side. Depending on the year of the upgrade, these could be Windows XP, 7, 8.1 or 10 machines. The Saw side PCgenerally maps a drive and runs its control software from a shared directory on the MH side computer.
 
  
 +
{{#annotatedImageLight:Fichier:Netmatters CNC PC.png|0=115px|hash=|jsondata=|mediaClass=Image|type=frameless|align=right|src=https://stuga.dokit.app/images/d/d4/Netmatters_CNC_PC.png|href=./Fichier:Netmatters CNC PC.png|resource=./Fichier:Netmatters CNC PC.png|caption=|size=115px}}
 +
A front end Pc is used to provide the user interface, which has a desktop split across two screens, one for each side of the machine. The front end software launches two UI forms, which has a slight downside in that two operators cannot use it at exactly the same time
  
Both PCs have a network port and are connected through a 5 port switch located in the MH cabinet
+
Uses a Gapton Computers or Netmatters supplied "CNC" machine
 +
 
 +
{{#annotatedImageLight:Fichier:PC Configuration - Flowline D C0001013.jpg|0=100px|hash=|jsondata=|mediaClass=Image|type=frameless|align=right|src=https://stuga.dokit.app/images/c/c0/PC_Configuration_-_Flowline_D_C0001013.jpg|href=./Fichier:PC Configuration - Flowline D C0001013.jpg|resource=./Fichier:PC Configuration - Flowline D C0001013.jpg|caption=|size=100px}}
 +
A "Back End" Beckhoff PC is used to provide the PLC control systems, running TwinCAT3. This is named F0nnB or F0nnBE (where nn is the build number).
 +
 
 +
Both PCs need to be on the same network
 +
 
 +
Front end PC needs TwinCAT3 Engineering Runtime installed, which allows communication to TwinCAT on the back end PC, and installs the System Manager to allow configuration and diagnostics of the front end.
 +
 
 +
The front end PC needs to have a "Route" set up to the Back end PC for TwinCAT to work
 
{| class="wikitable"
 
{| class="wikitable"
 
|+Folder Structure
 
|+Folder Structure
!MH Setup Files
+
!Setup Files
!Saw Setup Files
+
!Front End Software
!MH Front End Software
 
!Saw Front End Software
 
 
|-
 
|-
|*.mul initialisation files<br /><syntaxhighlight lang="dosbatch">
+
|*.mul and *.saw initialisation files<br /><syntaxhighlight lang="dosbatch">
c:\
+
c:\ddrive\
</syntaxhighlight>
 
|*.saw initialisation files<br /><syntaxhighlight>
 
d:\
 
 
</syntaxhighlight>
 
</syntaxhighlight>
 
|written in vb.net <br /><syntaxhighlight>
 
|written in vb.net <br /><syntaxhighlight>
 
c:\multi\winmulti.exe
 
c:\multi\winmulti.exe
 
</syntaxhighlight>
 
</syntaxhighlight>
|written in vb.net <br /><syntaxhighlight>
+
|}Location of folder structure of MH side can be changed in the local masterdir.saw. See [https://stuga.dokit.app/w/Masterdir_File https://stuga.dokit.app/wiki/Masterdir_File]
d:\winStugaSawVB.exe
+
{{Info|...The default folder used is called "DDRIVE" for historical reasons. Some other machines have aBeckhoff PC as the front end which has limited HDD space. In this case, a secondary PC was set up for diagnostics / storage (sometimes referred to as the "Camera PC"). The DDRIVE was set up as a shared folder on the Camera PC to store all machine data and diagnostics, which was mapped as "D:\" from the front end}}
</syntaxhighlight>
 
|}Location of folder structure of MH side and saw side can be changed in the local masterdir.saw. See [https://stuga.dokit.app/w/Masterdir_File https://stuga.dokit.app/wiki/Masterdir_File]
 
 
<br />
 
<br />
 
=PCs=
 
=PCs=
Historically, these PCs could be one of a number of different hardwares
+
</translate>
 
 
*ACER Revo (Windows XP, 7, 8.1)
 
*Gapton or Netmatters supplied "CNC" machine
 
 
 
 
 
{{#annotatedImageLight:Fichier:Netmatters CNC PC.png|0=115px|hash=|jsondata=|mediaClass=Image|type=frameless|align=right|src=https://stuga.dokit.app/images/d/d4/Netmatters_CNC_PC.png|href=./Fichier:Netmatters CNC PC.png|resource=./Fichier:Netmatters CNC PC.png|caption=|size=115px}}</translate>
 
 
{{PageLang
 
{{PageLang
 +
|Language=en
 
|SourceLanguage=none
 
|SourceLanguage=none
 
|IsTranslation=0
 
|IsTranslation=0
|Language=en
 
 
}}
 
}}
 
{{AddComments}}
 
{{AddComments}}

Version du 12 novembre 2019 à 11:54

Auteur avatarGareth Green | Dernière modification 12/11/2019 par Gareth Green en cours de rédaction

PC network configuration of the Flowline following using a Beckhoff TwinCAT3 system which controls both the saw and windows side.

Following a second wave of obsolescence, this upgrade replaces all the control components with a Beckhoff control system. The major change to this system is that it uses one central system to control both sides of the machine.

Netmatters CNC PC.png

A front end Pc is used to provide the user interface, which has a desktop split across two screens, one for each side of the machine. The front end software launches two UI forms, which has a slight downside in that two operators cannot use it at exactly the same time

Uses a Gapton Computers or Netmatters supplied "CNC" machine

PC Configuration - Flowline D C0001013.jpg

A "Back End" Beckhoff PC is used to provide the PLC control systems, running TwinCAT3. This is named F0nnB or F0nnBE (where nn is the build number).

Both PCs need to be on the same network

Front end PC needs TwinCAT3 Engineering Runtime installed, which allows communication to TwinCAT on the back end PC, and installs the System Manager to allow configuration and diagnostics of the front end.

The front end PC needs to have a "Route" set up to the Back end PC for TwinCAT to work

Folder Structure
Setup Files Front End Software
*.mul and *.saw initialisation files
c:\ddrive\
written in vb.net
c:\multi\winmulti.exe

Location of folder structure of MH side can be changed in the local masterdir.saw. See https://stuga.dokit.app/wiki/Masterdir_File

...The default folder used is called "DDRIVE" for historical reasons. Some other machines have aBeckhoff PC as the front end which has limited HDD space. In this case, a secondary PC was set up for diagnostics / storage (sometimes referred to as the "Camera PC"). The DDRIVE was set up as a shared folder on the Camera PC to store all machine data and diagnostics, which was mapped as "D:\" from the front end


PCs

Commentaires

Draft