Setup follows the format of two independent machines with independent control systems - MH (Multi-Head) side and saw side. The MH side is a more powerful Industrial PC with Hard drive running an early Windows OS. The Saw side PC is a much smaller DOS based system, containing DOS boot and network software to map a drive and run its control software from a shared directory on the MH side computer.
 
Setup follows the format of two independent machines with independent control systems - MH (Multi-Head) side and saw side. The MH side is a more powerful Industrial PC with Hard drive running an early Windows OS. The Saw side PC is a much smaller DOS based system, containing DOS boot and network software to map a drive and run its control software from a shared directory on the MH side computer.
  
Ligne 19 : Ligne 19 :
 
!Saw Front End Software
 
!Saw Front End Software
 
|-
 
|-
|MH Side <br />
+
|*.mul initialisation files<br /><syntaxhighlight lang="dosbatch">
|MH Side<syntaxhighlight>
+
c:\
c:\saw\
 
 
</syntaxhighlight>
 
</syntaxhighlight>
|
+
|*.saw initialisation files<br /><syntaxhighlight>
|
+
d:\
|-
+
</syntaxhighlight>
|c:\
+
|<br /><syntaxhighlight>
|
+
c:\multi.exe
|
+
</syntaxhighlight><br />
|
+
|<br /><syntaxhighlight>
|-
+
d:\saw.exe
|
+
</syntaxhighlight><br />
|
 
|
 
|
 
 
|}
 
|}
<br />
+
=Saw Side PC=
 
 
= Saw Side PC =
 
 
{{#annotatedImageLight:Fichier:ACEpc.png|0=179px|hash=|jsondata=|mediaClass=Image|type=frameless|align=right|src=https://stuga.dokit.app/images/1/12/ACEpc.png|href=./Fichier:ACEpc.png|resource=./Fichier:ACEpc.png|caption=|size=179px}}<br />
 
{{#annotatedImageLight:Fichier:ACEpc.png|0=179px|hash=|jsondata=|mediaClass=Image|type=frameless|align=right|src=https://stuga.dokit.app/images/1/12/ACEpc.png|href=./Fichier:ACEpc.png|resource=./Fichier:ACEpc.png|caption=|size=179px}}<br />
  
* Arcom ACEpc running DOS
+
*Arcom ACEpc running DOS
* 8Mb Flash Drive containing ROM-DOS to boot up
+
*8Mb Flash Drive containing ROM-DOS to boot up
* Uses NetBEUI or TCP-IP to share all setup data from MH side PC
+
*Uses NetBEUI or TCP-IP to share all setup data from MH side PC
* Maps d:\ to MH SAW shared directory for all control software
+
*Maps d:\ to MH SAW shared directory for all control software
* Old units available for loan
+
*Old units available for loan
* Instructions in dokit for reflashing drive and programming TCP-IP
+
*Instructions in dokit for re-flashing drive and programming TCP-IP [[Manual:ACE PC|https://stuga.dokit.app/wiki/Manual:ACE_PC]]
* Serial port COM1 used to send instructions to Smartmove/1 or Nextmove ESB Motion control card
+
*Serial port COM1 used to send instructions to Smartmove/1 or Nextmove ESB Motion control card
* Serial Port COM2 used for printer
+
*Serial Port COM2 used for printer
* Located in Saw console
+
*Located in Saw console
  
  
= MH Side PC =
+
=MH Side PC=
 
{{#annotatedImageLight:Fichier:Arcom APC.png|0=201px|hash=|jsondata=|mediaClass=Image|type=frameless|align=right|src=https://stuga.dokit.app/images/a/a5/Arcom_APC.png|href=./Fichier:Arcom APC.png|resource=./Fichier:Arcom APC.png|caption=|size=201px}}<br />
 
{{#annotatedImageLight:Fichier:Arcom APC.png|0=201px|hash=|jsondata=|mediaClass=Image|type=frameless|align=right|src=https://stuga.dokit.app/images/a/a5/Arcom_APC.png|href=./Fichier:Arcom APC.png|resource=./Fichier:Arcom APC.png|caption=|size=201px}}<br />
  
* Arcom APC running Windows 95 or 98
+
*Arcom APC running Windows 95 or 98
* IDE HDD
+
*IDE HDD
* Uses NetBEUI or TCP-IP to share all setup data from MH side PC and share a folder for batch writing
+
*Uses NetBEUI or TCP-IP to share all setup data from MH side PC and share a folder for batch writing
* Old units available for loan
+
*Old units available for loan
* Contains Nextmove PC motion control card on ISA bus to control Machining centre axes and IO
+
*Contains Nextmove PC motion control card on ISA bus to control Machining centre axes and IO
* Located in a box next to machining centre door
+
*Located in a box next to machining centre door
 
 
<br />{{#annotatedImageLight:Fichier:Nextmove PC Card.png|0=235px|hash=|jsondata=|mediaClass=Image|type=frameless|align=right|src=https://stuga.dokit.app/images/b/b1/Nextmove_PC_Card.png|href=./Fichier:Nextmove PC Card.png|resource=./Fichier:Nextmove PC Card.png|caption=|size=235px}}<br />
 
  
== Nextmove PC Card and Breakout Panel ==
+
<br />{{#annotatedImageLight:Fichier:Nextmove PC Card.png|0=235px|hash=|jsondata=|mediaClass=Image|type=frameless|align=right|src=https://stuga.dokit.app/images/b/b1/Nextmove_PC_Card.png|href=./Fichier:Nextmove PC Card.png|resource=./Fichier:Nextmove PC Card.png|caption=|size=235px}}
 +
==Nextmove PC Card and Breakout Panel==
 
<br />{{#annotatedImageLight:Fichier:Nextmove Breakout Panel.png|0=208px|hash=|jsondata=|mediaClass=Image|type=frameless|align=right|src=https://stuga.dokit.app/images/c/cc/Nextmove_Breakout_Panel.png|href=./Fichier:Nextmove Breakout Panel.png|resource=./Fichier:Nextmove Breakout Panel.png|caption=|size=208px}}The control signals for the machine are presented via a 100 way D connector at the back of the Nextmove card. A multicore cable connects this to the Breakout Board to allow individual wires and cables to be connected to axis drives, inputs and outputs.
 
<br />{{#annotatedImageLight:Fichier:Nextmove Breakout Panel.png|0=208px|hash=|jsondata=|mediaClass=Image|type=frameless|align=right|src=https://stuga.dokit.app/images/c/cc/Nextmove_Breakout_Panel.png|href=./Fichier:Nextmove Breakout Panel.png|resource=./Fichier:Nextmove Breakout Panel.png|caption=|size=208px}}The control signals for the machine are presented via a 100 way D connector at the back of the Nextmove card. A multicore cable connects this to the Breakout Board to allow individual wires and cables to be connected to axis drives, inputs and outputs.
  
Ligne 71 : Ligne 64 :
 
<br /></translate>
 
<br /></translate>
 
{{PageLang
 
{{PageLang
 +
|Language=en
 
|SourceLanguage=none
 
|SourceLanguage=none
 
|IsTranslation=0
 
|IsTranslation=0
|Language=en
 
 
}}
 
}}
 
{{AddComments}}
 
{{AddComments}}

Version actuelle datée du 12 novembre 2019 à 08:21

Auteur avatarGareth Green | Dernière modification 12/11/2019 par Gareth Green en cours de rédaction

PC network configuration of the original Flowline

Summary

Setup follows the format of two independent machines with independent control systems - MH (Multi-Head) side and saw side. The MH side is a more powerful Industrial PC with Hard drive running an early Windows OS. The Saw side PC is a much smaller DOS based system, containing DOS boot and network software to map a drive and run its control software from a shared directory on the MH side computer.


Both PCs have a network port and are connected through a 5 port switch located in the MH cabinet

Folder Structure
MH Setup Files Saw Setup Files MH Front End Software Saw Front End Software
*.mul initialisation files
c:\
*.saw initialisation files
d:\

c:\multi.exe


d:\saw.exe

Saw Side PC

ACEpc.png


  • Arcom ACEpc running DOS
  • 8Mb Flash Drive containing ROM-DOS to boot up
  • Uses NetBEUI or TCP-IP to share all setup data from MH side PC
  • Maps d:\ to MH SAW shared directory for all control software
  • Old units available for loan
  • Instructions in dokit for re-flashing drive and programming TCP-IP https://stuga.dokit.app/wiki/Manual:ACE_PC
  • Serial port COM1 used to send instructions to Smartmove/1 or Nextmove ESB Motion control card
  • Serial Port COM2 used for printer
  • Located in Saw console


MH Side PC

Arcom APC.png


  • Arcom APC running Windows 95 or 98
  • IDE HDD
  • Uses NetBEUI or TCP-IP to share all setup data from MH side PC and share a folder for batch writing
  • Old units available for loan
  • Contains Nextmove PC motion control card on ISA bus to control Machining centre axes and IO
  • Located in a box next to machining centre door


Nextmove PC Card.png

Nextmove PC Card and Breakout Panel


Nextmove Breakout Panel.png

The control signals for the machine are presented via a 100 way D connector at the back of the Nextmove card. A multicore cable connects this to the Breakout Board to allow individual wires and cables to be connected to axis drives, inputs and outputs.