[version en cours de rédaction] | [version en cours de rédaction] |
Ligne 5 : | Ligne 5 : | ||
|Categories=Production | |Categories=Production | ||
|Difficulty=Medium | |Difficulty=Medium | ||
− | |Duration= | + | |Duration=2 |
|Duration-type=hour(s) | |Duration-type=hour(s) | ||
}} | }} |
Instructions to bench assemble pneumatic rail
Auteur Gareth Green | Dernière modification 3/04/2024 par Gareth Green en cours de rédaction ⧼frevu-button-review-label⧽
Instructions to bench assemble pneumatic rail
R0015095_Bench_Assemble_Pneumatic_Rail_Screenshot_2023-06-13_080803.png
Tools Required
Standard spanner set
Standard hex key set
Pipe cutters
Standard screwdriver set
Parts Required
D0016300 x 1
P0001074 x 8
P0001101 x 2
P0001102 x 2
P0001071 x 1
P0001186 x 10
P0001068 x 1
P0000470 x 1
P0001040 x 2
P0000010 x 6
P00000007 x 2
P0000142 x 1
P0001008 x 2
D0010167 x 2
C0001018 x 2
P0001022 x 2
P0001009 x 2
P0001108 x 4
P0001166 x 1
P0001106 x 1
Use Loctite 243 on all fasteners
Use Loctite 572 on all threaded pneumatic connections
Pen mark all bolts to show finalised
If Machine is R to L build rail as shown
If machine is L to R build rail mirrored to layout shown
Assembly valve bank as shown using
P0001074 x 4
P0001101 x 1
P0001102 x 1
P0001071 x 1
P0001186 x 8
Assembly valve bank as shown using
P0001074 x 4
P0001101 x 1
P0001102 x 1
P0001068 x 1
P0001186 x 2
Assemble fittings onto valve P0000470 using
P0001040 x 2
P0000010 x 2
p0000007 x 2
P0000142 x 1
Assemble 2 off P0001008 regulators with fittings as listed
P0000010 x 4
Mount 2 off C0001018 Ethercat boxes to mounting plates D0010167 2 off using M3 x 20 Pan head fasteners
Attach a length of 75mm x 25mm trunking @ 1310mm, 120mm from non slotted end to rear of maytec and use M5 x 6 button sockets to secure
Ecr raised to add holes to maytec section on 05/09/23
Holes will required drilling until ecr finalises
1st m5 hole 130mm from non slotted hole end , then spaced at 250mm Drill and tap m5
Mount assembled components onto mounting bar D0016300 as shown
Space as follows
Position 1st ethercat box 100mm for end of maytec beam ( non slotted hole end )
All mounted components to be spaced 100mm apart
Except for
Ethercat boxes to butt together
Valve to valve bank 1 , set to 70mm
Valve B1 and Valve B2 spaced at 130mm
Use following fixings
Each regulator mounted with P0001022 bracket and P0001009 nut, fastened with M5 x 12 socket caps and washers
Valve bank 1 and 2 secured with M4 x 40 socket caps and M8 motor plate washers, spaced away from maytec rail with 2 M8 washers to enable valve to sit straight
Ethercats Mounted with M6 x 16 socket caps and A form washers.
Valve mounted with M4 x 30 socket caps, and M4 D nuts. ( one d nut will require cutting to shorten to allow fitment )
Use D nuts to provide fixing points into rail
Additional photo required to show additional 4th 12mm tee connection
Connect 12mm and 8mm blue air lines as shown
Use fittings
P0001108 x 4
P0001166 x 1
p0001106 x 1
en none 0 Draft
Vous avez entré un nom de page invalide, avec un ou plusieurs caractères suivants :
< > @ ~ : * € £ ` + = / \ | [ ] { } ; ? #