  • 1 Use green strip on indicated loader arm1 Use green strip on indicated loader arms and yellow 1 meter level to read level of arms indicated 2 Adjust level of arms using jacking points below.
    ...Always check previous adjusted loading arm isn't affected by changes to the next arm
    Recheck all levels on arms are correct once final arm has been adjusted
    /div> </div> Recheck all levels on arms are correct once final arm has been adjusted  +
  • 1 Use Module B horizontal datum rollers to1 Use Module B horizontal datum rollers to position laser level on 2 Cast Beam from laser along infeed frame approximately 30mm away from back fence 3 Take measurement on level arm 1 at the indicated point from green runner strip to laser line 4 Measure and adjust level arm 9 to set to same as the first measured arm Ensure adjustment points are altered in pairs with exact turns to ensure Y axis level is not lost 5 Repeat process at arms 3,5,6 and 8 repeating the same measurement as taken at arm 1
    me measurement as taken at arm 1 <br/>  +
  • 12mm blue pipe trailing from infeed table should be connected to module B air service unit Leave pipe over length to allow final fitment during on site installation  +
  • A laser must be used to ensure the backfeA laser must be used to ensure the backfence of the infeed is aligned along its entire length 1 Place laser against vertical rollers in module B, casting line over infeed table. 2 Take measurement of laser beam to first backfence closest to Module B 3 Take same measurement at furthest backfence , this will identify the misalignment if present as both figures need to be the same
    s both figures need to be the same <br/>  +
  • Fit Light curtain [parts to module B  +
  • Height difference between module B datum rHeight difference between module B datum rollers and infeed rollers should now be finalised Adjust to set infeed roller 0.5mm - 1mm below Module B Datum rollers . Use Jacking points on frame and ensure all points are rotated equally to ensure previous settings remainequally to ensure previous settings remain  +
  • Module A height must now be adjusted to maModule A height must now be adjusted to match the height of Module B datum rollers Ensure the adjustment points are always turned the EXACT same rotation when adjusting. This will ensure that Y axis level is not compromised Adjust height to match height of Module B datum rollers. Tolerance -+1mmatch height of Module B datum rollers. Tolerance -+1mm  +
  • Now the modules have been aligned , Safety light curtain should be fitted from R0015266B  +
  • Please now quality check all settings for Please now quality check all settings for accuracy and correct setting 1 Y axis levels all correct and within sight lines of level 2 X axis level all correct and no greater error 3 Backfence alignment . Infeed backfence is set to the correct distance behind Module B datum rollers 4 Roller height is set to 1mm (-+0.5mm) lower than module B datum rollers-+0.5mm) lower than module B datum rollers  +
  • Position module A in front of module B Use Infeed back fence to Multi head datum rollers as initial alignment guide for Y axis Set gap of 23mm -+ 2mm between module A roller frame and module B roller block  +
  • To adjust the measurement, the end B of thTo adjust the measurement, the end B of the infeed frame must be moved in the direction required to correct the measurement
    ...Adjusting this end will cause end A to move, and change the backfence to roller alignment. This will have to be checked and reset
    Keep adjusting End A and B until the following are correct Laser measurement is less than 2mm in difference from End A to B Backfence alignment at End A is 1mm (tolerance -+0.5mm) behind the module datum rollers
    A to B Backfence alignment at End A is 1mm (tolerance -+0.5mm) behind the module datum rollers  +
  • Use 2 meter straight edge to confirm alignUse 2 meter straight edge to confirm alignment of roller beds once levelled Move straight edge over roller assemblies to confirm there is no bump onto neighbouring rollers and all rollers are flat to straight edge Report any discrepancies to supervisor for suggested remedial actiono supervisor for suggested remedial action  +
  • Use a 2 meter straight edge to check that first 4 stainless back fences are correctly aligned to straight edge. Contact should be as shown  +