  • Click Apply Username is Administrator and password is the standard Stuga one  +
  • Ensure all devices are in OP mode  +
  • See [[Archiving a TwinCAT Project]]  +
  • Shut down all the pcs, saving projects, etc and perform a full power cycle  +
  • Take care to ensure all cables are replaced in the same relative positions Power on  +
  • Teamviewer in to the new beckhoff PLC ("BE") Set * IP Address * Subnet Mask * Default Gateway These addresses should be stored in the DDRIVE of the front end PC in IP.mul  +
  • This is done using the TwinCAT Visual StudThis is done using the TwinCAT Visual Studio interface. The location of the Visual Studio project will depend on the setup and age of the machine. Generally this is one of 3 places, to find out, use teamviewer database to list the computers associated with the machine # If the PC has a "VM" virtual machine installed (2023 onwards), a project will be set up on this desktop - use Teamviewer to connect # If the PC has a "C" camera machine (only selected customers and older TwinCAT2 machines) # On the main front end PC (operator desktop)n the main front end PC (operator desktop)  +
  • This step programs the project with the MaThis step programs the project with the Mac address of the ethernet port for the system to use as the connection to the TwinCAT system. There are two ports on the front of the Beckhoff unit, Ethernet (Yellow cable) plugs in one, EtherCAT(green cable) in the other. # Double click devices # Adapter tab # Click Search # Select the "EtherCAT" Port (This may not be named correctly, one port is used for EtherCAT, the other for Ethernet) # Click okherCAT, the other for Ethernet) # Click ok  +
  • This step tells the front end the AMS net Id of the backend. The AMS net Id should be different for every Beckhoff PLC created Two parameters need to be set amsNetId=[xxx.xxx.xxx.xxx].1.1 twinCATAddress=[xxx.xxx.xxx.xxx].1.1 <br/>  +