Rechercher dans les propriétés de la page

Rechercher dans les propriétés de la page

Entrer soit une page et une propriété, ou seulement une propriété, pour récupérer toutes les valeurs affectées.

Affichage de 10 résultats à partir du n°1.

Voir (20 précédentes | 20 suivantes) (20 | 50 | 100 | 250 | 500).


    

Liste de résultats

  • Disconnect pcl air supply Remove temporary blanks fitted  +
  • Fire and hold valve Blowers should switcFire and hold valve Blowers should switch on Check operation of inline flow controllers . When fully closed air flow should stop completely. If air flow can not be completely stopped by flow controller, it is fitted the wrong way around. Change and recheck if this occursaround. Change and recheck if this occurs  +
  • Fire and hold valve Infeed side z block should fire towards back fence Should retract when valve released  +
  • Fire and hold valve Infeed turret should rotate once Release and fire valve again and turret should again rotate one position  +
  • Fire and hold valve Saw head should raise up Should retract when valve released Adjust damper thumb wheel to allow good speed when saw cut stroke upwards  +
  • Fire and hold valve Set regulator to 0.2 M.P.A Saw head should move towards rear of machine Should retract when valve released <br/>  +
  • Fire and hold valve Outfeed side z block should fire towards back fence Should retract when valve released  +
  • Fire and hold valve Outfeed turret should rotate once Release and fire valve again and turret should again rotate one position  +
  • Output testing will require valve operatioOutput testing will require valve operation with no e/s circuit Ensure the following Work area is clear from all components not required for testing All colleagues are aware of the procedure being undertaken No additional colleagues are working on the module PCL coupling is accessible to release pressure in case of emergency Testing procedure is fully adhered tocy Testing procedure is fully adhered to  +
  • assistance required from colleague Fire assistance required from colleague Fire and hold Y80 output , infeed top clamp should move down. Keep Y80 held down Top clamp block pressure should be weak enough to override by hand and move clamp back towards cylinder Additionally fire Y212, this should switch clamp to high pressure and stop clamp being able to be over ridden by handclamp being able to be over ridden by hand  +