Rechercher dans les propriétés de la page

Rechercher dans les propriétés de la page

Entrer soit une page et une propriété, ou seulement une propriété, pour récupérer toutes les valeurs affectées.

Affichage de 10 résultats à partir du n°1.

Voir (20 précédentes | 20 suivantes) (20 | 50 | 100 | 250 | 500).


    

Liste de résultats

  • 1 When air is connected, all cylinders should be in a contracted state. This is their home position <br/>  +
  • 4 off Check that when valve is activated, spindle assembly goes to the position shown. Fire valve a few times to check movement is consistent. Cylinder speeds and cushioning will be set at a later point  +
  • 4 off Check that when valve is activated4 off Check that when valve is activated, spindle assembly goes to the position shown. Fire valve a few times to check movement is consistent. Cylinder speeds and cushioning will be set at a later point 1 Single stage cylinder activated by lower valve , see image for details 2 Double stage cylinder activated by upper valve , see image for details
    upper valve , see image for details <br/>  +
  • All lubrication points should be greased 2 pumps of grease to be added to each linear bearing 24 off bearings in total 4 off bearings per double slide base 2 off bearings per single slide base  +
  • Compressed air feed needs connecting to maCompressed air feed needs connecting to main 6mm blue feed pipe to ring. Use adapter to enable safe connection via PCL coupling and probe
    ...Spindles may move when air feed is connected. Ensure no parts or persons are in the areas of movement
    onnected. Ensure no parts or persons are in the areas of movement</div> </div>  +
  • If correct practice has been followed, onIf correct practice has been followed, only the double slide cylinder will have the possibility of being at the incorrect home position . This is easily rectified 1 Image shows incorrect position when air has been connected to mains supply 2 To rectify, disconnect mains air feed and swap the two indicated pipes at the stem elbows 3 Reconnect air and confirm correct home position is now achievedfirm correct home position is now achieved  +
  • Once pneumatic testing is complete disconnect the air supply  +
  • Once testing is complete, oversized 4mm pipe looms can be shortened to the correct length as shown. Loom length should be as minimal as possible to avoid damage 4 off spindles to finalise  +
  • Valves can be activated manually by the control button. When pressed, the valve will fire the associated cylinder to its active position . 1 Manual valve activation button  +
  • When air is connect to rotary ring, attention should be paid to any audible air leaks. If any are present, identify source and rectify  +