  • 1 Fit 4 of P0000295 fittings to position cylinders 2 Fit 3 off P0000295 fittings to top clamp cylinders 3 Fit 1 off straight P0000007  +
  • 1 Ream with 8mm hand reamer to ensure cor1 Ream with 8mm hand reamer to ensure correct fitment 2 Fit 3 off shafts to block 3 Fit 6 off 8mm circlips to shafts 4 Fit 3 off retaining M5 x 6 grubscrews , ensuring dimples on shafts are aligned 5 Press 6 off bearings onto shafts . Use socket to enable final positioning of bearing against circlip 6 Add 6 off 8mm circlip to shafts to captivate bearings Ensure bearings run consistant and smoothlynsure bearings run consistant and smoothly  +
  • 1 Fit 4 off bottom bearings until ball ch1 Fit 4 off bottom bearings until ball chamber just disappears into bore 2 Press in 4 off top bearing until contacting bottom bearing 3 Fit 4 off retainer ring . Ensure not gap is present between block and ring Ensure all bearings are adequately greased once fittedearings are adequately greased once fitted  +
  • 1 Fit 2 off cylinder mounts as shown usin1 Fit 2 off cylinder mounts as shown using 4 of M5 x 12 socket caps Ensure correct orientation , alignment of flat is the datum 2 Caution on fitment of shafts, do not force into position Fit 4 off shafts to clamp heads and secure with 2 off M8 x 12 kcp and 2 off M8 x 16 kcp grubscrews as shown and 2 off M8 x 16 kcp grubscrews as shown  +
  • All bolts to have Loctite 243 adhesive applied unless otherwise stated All Threaded Pneumatic connections to have Loctite 570 applied All bolts to be pen marked once adhesive applied and correct tension added  +
  • Assemble hard stops 2 off 1 ECR Raised Assemble hard stops 2 off 1 ECR Raised to add flat to hard stop . Until processed add by hand , try and make a parallel flat not tapered as in picture 2 Linish heads of 2 off M6 x 16 socket caps to provide flat strike face 3 Add to hard stop block combining 2 off M6 nuts , ensure loctite 243 is used 4 Insert into mounting bracket and fit with M6 x 10 kcp grubscrews 5 Use vernier to set shown distance 50mmm when locking nut is tensioned . Tolerance -+ 0.2mmking nut is tensioned . Tolerance -+ 0.2mm  +
  • Degrease main blocks with Fe10 as shown  +
  • Ecr raised to include adding of hard stop at manufacture To fit hard stops 1 Cut thread of m5 x 60 socket cap to 10mm 2 Use loctite 270 and screw into indicated holes of pillars 3 Reduced shank of bolt to 10mm and dress to neaten  +
  • Fit shaft mounts insert pillars and secure with quip clamp handle as shown  +
  • Fit shafts and secure with 4 off M8x 8 kcp grubscrews  +
  • Lubricate All previous fitted bearings with trojan food safe grease as shown  +
  • Test fit shafts indicated into blocks to check for correct fitment . Check that shafts enter bore fully an dimples on shafts are able to align with locating tapped holes  +
  • Use dolly to press bearings into head blocks as shown Bearings to sit level at indicated points  +