Rechercher dans les propriétés de la page

Rechercher dans les propriétés de la page

Entrer soit une page et une propriété, ou seulement une propriété, pour récupérer toutes les valeurs affectées.

Affichage de 8 résultats à partir du n°1.

Voir (20 précédentes | 20 suivantes) (20 | 50 | 100 | 250 | 500).


    

Liste de résultats

  • # Set the rotary switch to the "RUN" position # Press and hold the "SET" button until the yellow and green LEDs stop flashing in phase (approx. 10 s) # If the green LED lights up, the procedure is complete   +
  • <div class="icon-instructions caution-i
    ...The Input is the reverse of expectation - low when assembly is in the out position
    reverse of expectation - low when assembly is in the out position</div> </div>  +
  • Rotary switch (4) to centre  +
  • See [[Technical Bulletin - Inverting Inputs]]  +
  • Select Q1  +
  • Temporarily place a length of profile offcTemporarily place a length of profile offcut of 70mm thickness in front to the laser dot (you will need another pair of hands to help)
    ...This shortens the laser distance to give us an "off threshold"

    *To store a switching threshold (distance measured value), press and hold the "SET" button until the yellow and green LEDs flash in phase (approx. 2 s). *Teach-In starts when the "SET" button is released. *A successful Teach-In is indicated by rapidly alternating flashing (2.5 Hz) of the yellow and green LEDs. *An unsuccessful Teach-In is indicated by alternating flashing (8 Hz) of the yellow and green LEDs.
    essful Teach-In is indicated by alternating flashing (8 Hz) of the yellow and green LEDs. <br/>  +
  • Via IO screen  +
  • • Short circuit: In the event of a short c• Short circuit: In the event of a short circuit at the sensor output, the green LED flashes with a frequency ofapprox. 4 Hz. • Teach error: In the event of a teach error, the yellow and green LEDs flash alternately with a frequency of approx. 8 Hz
    ...Note! The difference in the taught-in distance measured values for the switching thresholds A and B must be greater than the switching hysteresis set in the sensor. On delivery, the switching hysteresis is 15 mm. If the difference in the taught-in measured values is the same as or smaller than the set switching hysteresis, the sensor will visually signal an unsuccessful Teach-In. The last distance measured value that was taught in will not be adopted by the sensor. Select a new distance measured value for switching threshold A or B with a greater difference between the switching thresholds. Teach in this distance measured value on the sensor again.

    sholds. Teach in this distance measured value on the sensor again.</div> </div><br/>  +