  • Additional photo required to show additional 4th 12mm tee connection Connect 12mm and 8mm blue air lines as shown Use fittings P0001108 x 4 P0001166 x 1 p0001106 x 1  +
  • Assemble 2 off P0001008 regulators with fittings as listed P0000010 x 4  +
  • Assemble fittings onto valve P0000470 using P0001040 x 2 P0000010 x 2 p0000007 x 2 P0000142 x 1 <br/>  +
  • Assembly valve bank as shown using P0001074 x 4 P0001101 x 1 P0001102 x 1 P0001068 x 1 P0001186 x 2  +
  • Assembly valve bank as shown using P0001074 x 4 P0001101 x 1 P0001102 x 1 P0001071 x 1 P0001186 x 8  +
  • Attach a length of 75mm x 25mm trunking @ Attach a length of 75mm x 25mm trunking @ 1310mm, 120mm from non slotted end to rear of maytec and use M5 x 6 button sockets to secure Ecr raised to add holes to maytec section on 05/09/23 Holes will required drilling until ecr finalises 1st m5 hole 130mm from non slotted hole end , then spaced at 250mm Drill and tap m5nd , then spaced at 250mm Drill and tap m5  +
  • If Machine is R to L build rail as shown If machine is L to R build rail mirrored to layout shown  +
  • Mount 2 off C0001018 Ethercat boxes to mounting plates D0010167 2 off using M3 x 20 Pan head fasteners  +
  • Mount assembled components onto mounting bMount assembled components onto mounting bar D0016300 as shown Space as follows Position 1st ethercat box 100mm for end of maytec beam ( non slotted hole end ) All mounted components to be spaced 100mm apart Except for Ethercat boxes to butt together Valve to valve bank 1 , set to 70mm Valve B1 and Valve B2 spaced at 130mm Use following fixings Each regulator mounted with P0001022 bracket and P0001009 nut, fastened with M5 x 12 socket caps and washers Valve bank 1 and 2 secured with M4 x 40 socket caps and M8 motor plate washers, spaced away from maytec rail with 2 M8 washers to enable valve to sit straight Ethercats Mounted with M6 x 16 socket caps and A form washers. Valve mounted with M4 x 30 socket caps, and M4 D nuts. ( one d nut will require cutting to shorten to allow fitment ) Use D nuts to provide fixing points into railD nuts to provide fixing points into rail  +
  • Use Loctite 243 on all fasteners Use Loctite 572 on all threaded pneumatic connections Pen mark all bolts to show finalised  +