  • Assemble as shown for R to L machine Mirror assembly for L to R machine  +
  • Assemble valve bank 1 as shown using P0001068 valve base x 1 P0001186 valve x 2 P0001101 fitting x 2 P0001163 fitting x 4 <br/>  +
  • Assemble valve bank 2 as shown using P0001071 valve base x 1 P0001186 valve x 8 P0001101 fitting x 1 P0001102 fitting x 1 P0001163 x 4 P0000159 x 4 ( information required for which ports to blank) <br/>  +
  • Attach Fitting P0001102 to valve P0001139 as shown . Add 2 off P0001032 silencers as indicated  +
  • Attach a length of 75mm x 25mm trunking Attach a length of 75mm x 25mm trunking @ 1310mm, 120mm from non slotted end to rear of maytec and use M5 x 6 button sockets to secure Ecr raised to add holes to maytec section on 05/09/23 Holes will required drilling until ecr finalises 1st m5 hole 130mm from non slotted hole end , then spaced at 250mm Drill and tap m5d , then spaced at 250mm Drill and tap m5  +
  • Attach built assemblies to mounting bar D0Attach built assemblies to mounting bar D0016300 as shown using the following fixings Space as follows 1st ethercat box 100mm from end of maytec non slotted end, second ethercat box butted against 1st. All other components should be spaced at 100mm except for Valve 1 and Valvebank 1 which are spaced at 150mm Valve 1 uses bracket P0001151 to attach using M4 x 12 socket caps and A form washers Valve bank 1 and 2 secured with M4 x 40 socket caps and M8 motor plate washers, spaced away from maytec rail with 2 M8 washers to enable valve to sit straight Ethercat mount plates use m6 x 16 socket caps and a form washers Connection box uses M4 x 12 socket caps and washersn box uses M4 x 12 socket caps and washers  +
  • Connect as shown using 12mm blue air pipe  +
  • Connection box A0000240 will require holes adding to use. Drill 2 off 5mm holes on back face to allow mounting on rail as shown. Use M4 socket caps and washers Drill top face to mount A0000105 gland and fix with A0000255 nut  +
  • Make sure identification markers are safely stored with assembly ready for electrical terminations at a later point  +
  • Mount ether cat boxes C0001018 to mounting plates D0010167 using m3 x 20 panhead bolts  +
  • Use Loctite 243 on all fasteners Use Loctite 572 on all pneumatic threaded connections Pen mark all fasteners to show finalised  +