  • All bolts to have Loctite 243 adhesive applied unless otherwise stated All Threaded Pneumatic connections to have Loctite 570 applied All bolts to be pen marked once adhesive applied and correct tension added  +
  • Loom cables across wire basket Ensure top 2 fixing points are not used for cables (required for pneumatics)  +
  • Please diagram to determine handing positions of machine sections  +
  • Route 25way cable as shown. Route from Rear Infeed to Rear outfeed positions Male plug to be positioned at Rear infeed position as shown <br/>  +
  • Route 4 off green cables and x120 into trunking through 2 off 20mm grommit holes Route servo cable as shown on cable tie bases Ensure large cable base is fitted and used at indicated point Exit cables at rear of machine  +
  • Route Cables as shown , to first energy chain , then through energy chain to exit point Ensure cable retention points on energy chain brackets are used  +
  • Route as shown power connection from wiring loom assembly Z105 onwards as pictures Z104 and below Different style plug mounted internally in trunking Route cable to rear of machine as shown  +
  • Route yellow and green network cables from loom box as shown Cables route from Rear outfeed to rear infeed as shown . Please clarify length of cable to be left extended from front or back of machine please  +
  • Use Servo cable identified V axis from wirUse Servo cable identified V axis from wiring loom box, and incorporate with previous step cables to enter next energy chain . Ensure cables are as shown and cable retention bracket is used to enable cables to be kept flat once fitted Exit cables from top of energy chained Exit cables from top of energy chain  +
  • Use cable AX2 and connect to width sensor Use cable AX2 and connect to width sensor assembly as shown For R-L configuration, cable must enter trunking and route across lower trunking from width sensor to FB03B connection box For L-R configuration (shown) connect cable to width sensor assembly, enter trunking then exit again for connection to FB03Bng then exit again for connection to FB03B  +
  • Use cable CB44B from wiring loom assembly. Exit lower infeed trunking as shown leaving 1.5 meters out of trunking . Route cable through trunking and exit at rear of frame  +
  • Use cable from loom box labelled EN04B Run from vertical trunking and exit cable at rear of machine <br/>  +
  • Use cable from loom box labelled EN05B Run from vertical trunking and exit cable at rear of machine  +
  • Use cable from loom box labelled EN06B Always fitted same side of machine as previous 2 fitted camera cables Run from vertical trunking and exit cable at rear of machine  +
  • Use cables CB01B for connection to VUse cables CB01B for connection to VI motor CB02B for connection to VO motor CB03B for connection to WI motor CB04B for connection to WO motor and already installed Cable x120 Motor identification should be determined by diagrams shownion should be determined by diagrams shown  +
  • Use cables CB532B and CB06B from wiring loom box. Fit as shown to Infeed Front position on frame. Route cables to exit at rear of frame  +
  • Use diagram to identify rear loom routing point For L-R cable loom should route to the right side (viewed from back ) For R-L cable loom should route to the left side (viewed from back )  +
  • Use pre wired guard switches from wiring lUse pre wired guard switches from wiring loom box CB45B Front interlock guard switch Cb46B Rear interlock guard switch Use diagram to determine position Run cable to rear exits of machine
    ...Gaurd switches will be fixed into position at a later point

    ...Gaurd switches will be fixed into position at a later point</div> </div> <br/>  +
  • Use step 3 for correct identification of pUse step 3 for correct identification of positions required Use 4 off cables from wiring loom box CB40B Front Infeed Hinge CB41B Front Outfeed Hinge CB42B Rear Infeed Hinge CB43B Rear Outfeed Hinge Ensure Tie base is used as shown , and star grommits are used for cable entry and exit through main frame work All Cables to exit at rear of machinek All Cables to exit at rear of machine  +
  • When fitting hinges in next step, it is vital that the supplied bungs with E0001176 hinges are fitted to hinges. These are vital for correct operation of hinges  +