  • 1 Set hole position A to middle of moveme1 Set hole position A to middle of movement in direction shown 2 Use engineers level on indicated face and adjust position B up or down to set rail level 3 Remove central fasteners one by one, applying adhesive and adding final tension. Then remove both end fasteners ,apply adhesive and apply final tension Repeat for all remaining 5 linear rails
    t for all remaining 5 linear rails <br/>  +
  • Attach B0000046 bearings 6 off to linear rAttach B0000046 bearings 6 off to linear rails orientated as shown Use M6 x 16 socket caps and M6 A form washers with adhesive and lightly fasten as shown , ensure mounting brackets are free to move to align to the bearing face . Once all faces are in position, tighten all fasteners with adhesive and finalisen all fasteners with adhesive and finalise  +
  • Attach D0015492 Vertical Beam Adjustment PAttach D0015492 Vertical Beam Adjustment Plate x 5 and D0015493 Lateral Beam Adjustment Plate x 5 to positions shown Use M10 x 20 and M10 x 30 set bolts, M10 A form washers And nuts on joining plates Pay attention to orientation of position 3 only apply light pressure to fasteners to hold in place bracketsure to fasteners to hold in place brackets  +
  • Brackets require fixing with 8mm x 24mm roll pins Drill the indicated faces to secure alignment All 5 bracket sets required pinning  +
  • Fit 6 off B0001006 linear rails to hepco bFit 6 off B0001006 linear rails to hepco beam as shown Use data for position of each rail Fix with F0000331 m6 threaded plates and m6 x 20 socket caps with no adhesive ( holding stock of F0000331 plates is available from stores via request ) only apply light pressure to 2 off fixings per raily light pressure to 2 off fixings per rail  +
  • Now alignment is complete, the finalising dowels supplied with the hepco rail can be fitted in the areas shown  +
  • Quality check required from supervisor before next step commences  +
  • Setting jigs can now be removed that are supporting hepco rail in 5 positions Fit B0000173 blanking plugs to linear rails. Ensure plugs are fitted flush to rail face, not below Grease all linear bearings on hepco rail  +
  • Use Loctite 243 on all fasteners Use Loctite 570 on all threaded pneumatic connections Pen mark all bolts once finalised  +