  • Adjust sensor to read indicated face. Set gap to -1mm Ensure sensor lock nut is not over tighten when finalising  +
  • All bolts must have Loctite 243 adhesive applied unless otherwise stated. All bolts must be marked with pen once completed to indicate adhesive and correct tension has been applied  +
  • Assemble as shown 2 off H0008379 Shaft 12mm: 263mm R Axis Limit Stainless x 2 and pre assembled slide finger block Do not add fixings yet Ensure slide finger is orientated the correct way  +
  • Double check all bolts are tensioned and marked  +
  • Ensure slide finger moves freely between 2 points indicated  +
  • Fit 2 off P0000235 dampers as shown Position lock nuts on the indicated faces  +
  • Fit 4 off B0000122 bushes to block D0008380E as shown Bushes must be pushed flush to face Check internal diameter of bushes once fitted by using 1 off H0008379 Shaft 12mm If fit is tight, use 12mm hand reamer to clean bore to 12mm  +
  • Fit cable tie bases with M4 x 6 button sockets  +
  • Orientation For R-L machines fit to point A For L-R machines fit to point B Use 2 off M5 x 40 socket caps with A form washers to secure D0010756 Proximity Switch Mounting Block as shown  +
  • Set dampers to the following spec With damper fully compressed, a 5mm gap should be present at the indicated point Set both sides to the same setting  +
  • Use 2 off M8 x 50 socket caps to fit D0008383 Cross Joiner as shown Ensure indicated faces are set flush  +
  • Use 4 off M6 x 16 socket caps and heavy M6 washers to fix shafts as shown Note, slight shaft float will be present, this is normal  +
  • Use 6 off M8 x 30 socket caps to fix D0007455 Stop Damper Housing OH to D0007454 Stop Sub Base OH D0008378 Stop Damper Housing to D0008377 Stop Sub Base Ensure indicated faces are mated together on assembly  +