  • # '''Verify Complete Safety Project''' # Then '''Verify Complete Safety Project (Hardware Level)'''   +
  • '''TwinSAFE Wizard:''' # When prompted input, username: Administrator, # Serial Number: (Copied from step above), # Password: TwinSAFE. # Then confirm.  +
  • <div class="icon-instructions info-icon
    ...Because you are working on a new PC, the physical hardware has changed. You need tell the project that the hardware is different
    The hardware can use 1 or 2 devices. For the EtherCAT network port device: # Double click # Device MAC Addresses, Device 4 > Adapter > select OS (NDIS) > Search > EtherCAT. This should automatically update the mac address. For the NDIS (PCI) Device Device 1 > Adapter > PIC > Search > BUS.
    atically update the mac address. For the NDIS (PCI) Device Device 1 > Adapter > PIC > Search > BUS.  +
  • AmsNetID the same on SYSTEM > Routes > “Target net ID”, must be the same as: SAFETY > ZX5_2_1 > ZX5_2_1 Project > Target System (Figure 1).  +
  • Copy the '''serial number''' (Figure 2) for use in next step  +
  • Go to SAFETY > ZX5_2_1 > ZX5_2_1 Project > TwinSafeGroup1 > TwinSafeGroup1.sal, and press the '''Safety Goggles Icon''' (Figure 3). This should show the Estop circuit in green if working correctly.  +
  • Go to: SAFETY > ZX5_2_1 > ZX5_2_1 Project > Target System. Press the refresh button to update the AmsNetID as it will currently have the ID if the machine that the software was copied from.    +
  • Open Solution and... 1: rename the solution to the current build (i.e. Z067). 2: rename the project to the current build.     +
  • Paste the solution on the ZX5 front end PC in C:/TwinCAT/Stuga.  +
  • The build needs to be the same machine typThe build needs to be the same machine type and have an identical EtherCAT box and drive setup You can create a backup in three ways # Create an archive of an open project (you need to run Visual Studio on the desktop of the machine in question) # Copy the contents of the c:\TwinCAT\Stuga\[BuildNo] folder from the "donor" to your new machine setup # Use VPN to connect to the back end of the machine and upload the project from the target, then save it locally. this needs a good internet connection and Teamviewer remote VPN installed on the remote Beckhoff PCte VPN installed on the remote Beckhoff PC  +
  • To get the safety toolbar go to: View > Toolbars > Check '''TwinCAT Safety'''. This will show the safety options.  +
  • Update EtherCAT devices. This compares theUpdate EtherCAT devices. This compares the solution’s EtherCAT boxes to the ones on the current build. Any differences between the current solution and the current build will be highlighted and explained by the system. Issues highlighted in RED are completely different to what the solution would expect. Issues highlighted in BLUE are ok, this suggests that a new version of hardware is being used but is compatible with the solution. To do this right click on the target device and press “Scan”. NOTE: If this does not work, repeat steps, save changes and online reset (Right click device x).s and online reset (Right click device x).  +