[version en cours de rédaction] | [version en cours de rédaction] |
(Page créée avec « {{Tuto Details |Main_Picture=CEMark.png |Main_Picture_annotation={"version":"2.4.6","objects":[{"type":"image","version":"2.4.6","originX":"left","originY":"top","left":-4... ») |
|||
Ligne 5 : | Ligne 5 : | ||
|Tags=Safety, safety Standards, Compliance | |Tags=Safety, safety Standards, Compliance | ||
}} | }} | ||
− | <translate>== 1. CE Safety Standards, Hazard Identification & Compliance == | + | <translate>==1. CE Safety Standards, Hazard Identification & Compliance== |
Consideration has been made to ensure that the ZX conforms to or exceeds all current international safety standards. | Consideration has been made to ensure that the ZX conforms to or exceeds all current international safety standards. | ||
− | === 1.1.Moving Slides and Rotating Ballscrews === | + | ===1.1.Moving Slides and Rotating Ballscrews=== |
The ZX machining centre has CNC Driven axes including a rotary axis which could present possible trapping and crushing dangers. This has been addressed by isolating and disabling these axes via approved safety hinges or locking safety switches fitted to all access doors. | The ZX machining centre has CNC Driven axes including a rotary axis which could present possible trapping and crushing dangers. This has been addressed by isolating and disabling these axes via approved safety hinges or locking safety switches fitted to all access doors. | ||
These switches control an approved safety gate relay which disables the Servo drives by removing voltage to them by de-energising the drive contactors. | These switches control an approved safety gate relay which disables the Servo drives by removing voltage to them by de-energising the drive contactors. | ||
− | === 1.2.Revolving Spindles === | + | ===1.2.Revolving Spindles=== |
The ZX has revolving spindles in the Multihead and a rotating blade in the Saw. | The ZX has revolving spindles in the Multihead and a rotating blade in the Saw. | ||
Consideration of any danger to the operator has been addressed by the interlocked guarding mentioned above. Neither spindles or saw will run if any of the interlocked guarding is open. | Consideration of any danger to the operator has been addressed by the interlocked guarding mentioned above. Neither spindles or saw will run if any of the interlocked guarding is open. | ||
− | === 1.3.Harmonised Safety Standards === | + | ===1.3.Harmonised Safety Standards=== |
It is considered that the machine meets the following safety standards. | It is considered that the machine meets the following safety standards. | ||
Ligne 25 : | Ligne 25 : | ||
'''Safety of Machinery: '''''Electrical Equipment of Machines BS EN60204-1 1998'' | '''Safety of Machinery: '''''Electrical Equipment of Machines BS EN60204-1 1998'' | ||
− | == 2. Emergency Stop Buttons == | + | ==2. Emergency Stop Buttons== |
There are 4 Emergency Stop buttons located around the ZX as shown below. | There are 4 Emergency Stop buttons located around the ZX as shown below. | ||
Ligne 34 : | Ligne 34 : | ||
The Multihead includes buttons on the control console and the machining centre. When pressed the buttons shuts off power to the complete ZX machine, stopping the Multihead and Saw operations. | The Multihead includes buttons on the control console and the machining centre. When pressed the buttons shuts off power to the complete ZX machine, stopping the Multihead and Saw operations. | ||
− | === 2.1.Safety Doors === | + | ===2.1.Safety Doors=== |
Doors on the Machining and Saw centres are linked to the Emergency Stop circuit such that you cannot open the doors until the individual machine has stopped. | Doors on the Machining and Saw centres are linked to the Emergency Stop circuit such that you cannot open the doors until the individual machine has stopped. | ||
Ligne 45 : | Ligne 45 : | ||
The '''Saw''' has 3 guard doors, which only open when the Saw has stopped. These are: | The '''Saw''' has 3 guard doors, which only open when the Saw has stopped. These are: | ||
− | * Front door | + | *Front door |
− | * Rear door | + | *Rear door |
− | * Top door | + | *Top door |
[PIC] | [PIC] | ||
Ligne 56 : | Ligne 56 : | ||
The three doors are interlinked to prevent the saw blade starting when any one is open. | The three doors are interlinked to prevent the saw blade starting when any one is open. | ||
− | === 2.2.Long Length Warning === | + | ===2.2.Long Length Warning=== |
When an offcut is produced that is longer than the length of the Saw Outfeed Table, then a warning siren sounds and the warning light on the Outfeed Table is illuminated. | When an offcut is produced that is longer than the length of the Saw Outfeed Table, then a warning siren sounds and the warning light on the Outfeed Table is illuminated. | ||
− | == 3. Ring Exhaust Valve == | + | ==3. Ring Exhaust Valve== |
The R axis Ring pneumatic circuit is fitted with a non return valve. This maintains air pressure to the slide bases after the main air has been dumped via the emergency stop. This enables the ring to be rotated manually without the slide bases moving. | The R axis Ring pneumatic circuit is fitted with a non return valve. This maintains air pressure to the slide bases after the main air has been dumped via the emergency stop. This enables the ring to be rotated manually without the slide bases moving. | ||
Ligne 68 : | Ligne 68 : | ||
''' Caution: When rotating the ring after releasing the slide base air pressure the spindles can slide under gravity. This presents a possible trapping hazard. Ensure that no part of the body is in the cutter path when rotating the ring and that the spindles have fully dropped before reaching inside the ring'''.</translate> | ''' Caution: When rotating the ring after releasing the slide base air pressure the spindles can slide under gravity. This presents a possible trapping hazard. Ensure that no part of the body is in the cutter path when rotating the ring and that the spindles have fully dropped before reaching inside the ring'''.</translate> | ||
{{PageLang | {{PageLang | ||
+ | |Language=en | ||
|SourceLanguage=none | |SourceLanguage=none | ||
|IsTranslation=0 | |IsTranslation=0 | ||
− | |||
}} | }} | ||
{{AddComments}} | {{AddComments}} |
Safety Standards and Compliance
Auteur Anonymous | Dernière modification 19/09/2019 par Anonymous en cours de rédaction ⧼frevu-button-review-label⧽
Safety Standards and Compliance
Safety, safety Standards, Compliance CEMark.png
Consideration has been made to ensure that the ZX conforms to or exceeds all current international safety standards.
The ZX machining centre has CNC Driven axes including a rotary axis which could present possible trapping and crushing dangers. This has been addressed by isolating and disabling these axes via approved safety hinges or locking safety switches fitted to all access doors.
These switches control an approved safety gate relay which disables the Servo drives by removing voltage to them by de-energising the drive contactors.
The ZX has revolving spindles in the Multihead and a rotating blade in the Saw.
Consideration of any danger to the operator has been addressed by the interlocked guarding mentioned above. Neither spindles or saw will run if any of the interlocked guarding is open.
It is considered that the machine meets the following safety standards.
Safety of Machinery: Code of Practice: BS5304 1988 with revisions
Safety of Machinery: Electrical Equipment of Machines BS EN60204-1 1998
There are 4 Emergency Stop buttons located around the ZX as shown below.
{PIC}
The Multihead includes buttons on the control console and the machining centre. When pressed the buttons shuts off power to the complete ZX machine, stopping the Multihead and Saw operations.
Doors on the Machining and Saw centres are linked to the Emergency Stop circuit such that you cannot open the doors until the individual machine has stopped.
The Machining Centre has front and rear doors, which are interlinked to prevent opening whilst in operation. They are linked to the Emergency Stop circuit. There is also a safety gate on the transfer table.
[PIC]
The Saw has 3 guard doors, which only open when the Saw has stopped. These are:
[PIC]
The front door only opens when the Saw has stopped, and the top and rear doors can only be opened if the front door is open.
The three doors are interlinked to prevent the saw blade starting when any one is open.
When an offcut is produced that is longer than the length of the Saw Outfeed Table, then a warning siren sounds and the warning light on the Outfeed Table is illuminated.
The R axis Ring pneumatic circuit is fitted with a non return valve. This maintains air pressure to the slide bases after the main air has been dumped via the emergency stop. This enables the ring to be rotated manually without the slide bases moving.
Should free movement of the slide bases be required the air pressure can be released via the ring exhaust valve. Once the air has been released the valve must be returned to the closed position.
Caution: When rotating the ring after releasing the slide base air pressure the spindles can slide under gravity. This presents a possible trapping hazard. Ensure that no part of the body is in the cutter path when rotating the ring and that the spindles have fully dropped before reaching inside the ring. en none 0
Draft
Vous avez entré un nom de page invalide, avec un ou plusieurs caractères suivants :
< > @ ~ : * € £ ` + = / \ | [ ] { } ; ? #