Instructions on how to change a Pneumax valve slice
Author Stuga Engineer | Last edit 20/09/2019 by Stuga Engineer under review ⧼frevu-button-review-label⧽
Instructions on how to change a Pneumax valve slice
valve, slice, pneumax, air Changing_Pneumax_Valve_slice_IMG_2481.jpg
Please ensure screwdriver is a good fit to avoid wearing the head of the screw.
Pull Valve slice off, holding at the bottom and top of the slice.
Ensure pins line up correctly and are carefully inserted. Push valve slice into position.
When tightening the screws, screw in 2 turns on each of the side until tight to ensure a square fit.